Available commands
The following run-time commands are available with the sensor:
Command Description Parameters
#HDLRPMnnnn$ Set spin rate from 300 to 1200 RPM
n flash memory (default is 600 RPM)
nnnn is an integer between 0300 and 1200
#HDLRPNnnnn$ Set spin rate from 300 to 1200 RPM
in RAM (default is 600 RPM)
nnnn is an integer between 0300 and 1200
#HDLIPAssssssssssssdddddddddddd$ Change source and/or destination
IP address
ssssssssssss is the source 12-digit IP address
dddddddddddd is the destination 12-digit
IP address
#HDLFOVsssnnn$ Change horizontal Field of View (HFOV) sss = starting angle in degrees; sss is an integer
between 000 and 360
nnn = ending angle in degrees; nnn is an
integer between 000 and 360
You can also upload calibration data from db.xml into flash memory and use GPS time synchronization.
.