Use this chart to troubleshoot common problems
with
the
sensor.
Use
this
chart
to
troubleshoot
common problems with the
sensor.
E
R
E A
N
M
A
N
E
N
A
N
E
No service or maintenance requirements or procedures
exist
for
the
sensors.
However,
elodyne
does
offer
a preventative maintenance
service for a fee. For service maintenance, please contact Velodyne at (408) 465-2800, of log on to our website at www.velodynelidar.com.
[
Unit does
n’t spin
Verify power connection and polarity.
Verify proper voltage
—
should be 16 volts
drawing about 3-4 amps.
Remove bottom cover and check inline 10 amp fuse.
Replace if necessary. Model No. ATM-10.
Unit spins but no data
Verify Ethernet wiring.
Verify packet output with another tool
(e.g. Ethereal/Wireshark).
No serial communication
Verify RS-232 cable connection.
Unit must be active and spinning for
RS-232 update.
It may take several tries for the update
to be effective.
P
r
o
b
l
e
m
R
e
s
o
l
u
t
i
o
n